Connectivity Guide

Table Of Contents
Port monitoring commands
description
Congures a description for the port monitoring session. The monitoring session can be: local, RPM, or ERPM.
Syntax
description string
Parameters string — Enter a description of the monitoring session. A maximum of 255 characters.
Default Not congured
Command Mode MONITOR-SESSION
Usage Information The no version of this command removes the description text.
Example
OS10(conf-mon-local-1)# description remote
OS10(conf-mon-rpm-source-5)# description "RPM Sesssion"
OS10(conf-mon-erpm-source-10)# description "ERPM Session"
Supported Releases 10.2.0E or later
destination
Sets the destination where monitored trac is sent to. The monitoring session can be local or RPM.
Syntax
destination {interface interface-type | remote-vlan vlan-id}
Parameters interface-type — Enter the interface type for a local monitoring session.
ethernet node/slot/port[:subport] — Enter the Ethernet interface information as the destination.
port-channel id-number — Enter a port-channel number as the destination, from 1 to 128.
vlan vlan-id —Enter a VLAN ID as the destination, from 1 to 4093.
remote-vlan vlan-id—Enter a remote VLAN ID as the destination for the RPM monitoring session, from 1
to 4093.
Default Not congured
Command Mode MONITOR-SESSION
Usage Information The no version of this command resets the value to the default.
Example
OS10(conf-mon-local-10)# destination interface port-channel 10
OS10(conf-mon-rpm-source-3)# destination remote-vlan 20
Supported Releases 10.2.0E or later
Layer 2 277