Connectivity Guide

no shutdown
switchport access vlan 1
Congure range of VLANs
OS10(config)# interface range vlan 1-100
OS10(conf-range-vl-1-100)#
Congure range of port channels
OS10(config)# interface range port-channel 1-25
OS10(conf-range-po-1-25)#
Switch-port proles
A port prole determines the enabled front-panel ports and supported breakout modes on Ethernet and unied ports. Change the port
prole on a switch to customize uplink and unied port operation, and the availability of front-panel data ports.
To change the port prole at the next reboot, use the switch-port-profile command with the desired prole, save it to the startup
conguration, and use the reload command to apply the changes.
1 Congure a platform-specic port prole in CONFIGURATION mode. For a standalone switch, enter 1/1 for node/unit.
switch-port-profile node/unit profile
2 Save the port prole change to the startup conguration in EXEC mode.
write memory
3 Reload the switch in EXEC mode.
reload
The switch reboots with the new port conguration and resets the system defaults, except for the switch-port prole and these congured
settings:
Management interface 1/1/1 conguration
Management IPv4/IPv6 static routes
System hostname
Unied Forwarding Table (UFT) mode
ECMP maximum paths
You must manually recongure other settings on a switch after you apply a new port prole and reload the switch.
NOTE
: After you change the switch-port prole, do not immediately back up and restore the startup le without using the
write memory command and reloading the switch using the reload command. Otherwise, the new prole does not take
eect.
Congure port prole
OS10(config)# switch-port-profile 1/1 profile-6
OS10(config)# exit
OS10# write memory
OS10# reload
Verify port prole
OS10(config)# show switch-port-profile 1/1
| Node/Unit | Current | Next-boot | Default |
|-------------+-------------------+-------------------|
| 1/1 | profile-2 | profile-2 | profile-1 |
Supported Profiles:
profile-1
profile-2
profile-3
profile-4
160