Connectivity Guide

Table Of Contents
iDRAC Organizationally-specic TLVs
These are the sub-types used in iDRAC custom TLVs.
1 — Originator Indicates the iDRAC string that is used as originator. This string enables external switches to easily identify iDRAC
LLDP PDUs.
2 — Port type Following are the applicable port types:
1 — iDRAC Port (dedicated).
2 — NIC Port.
3 — iDRAC and NIC Port (shared).
3 — Port FQDD Port number that uniquely identies a NIC port within a server.
4 — Server service
tag
Service tag ID of the server.
5 — Server model
name
Model name of the server. For example, PowerEdge FC640.
6 — Server slot
number
Slot number of the server. For example, 1, 2, 3, 1a, 1b, and so on. The slot number is applicable to blade servers only.
7 — Chassis service
tag
Service tag ID of the chassis. (Applicable only to blade servers.)
8 — Chassis model Model name of the chassis. (Applicable only to blade servers.)
9 — IOM service
tag
Service tag ID of the IOM device. (Applicable only to blade servers.)
10 — IOM model
name
Model name of the IOM device. (Applicable only to blade servers.)
11 — IOM slot label Slot label of the IOM device. For example, A!, B!, A2, B2, and so on. (Applicable only to blade servers.)
12 — IOM port
number
Port number of the NIC. For example, 1, 2, 3, and so on.
Isilon related TLVs
These are the sub-types used in LLDP custom TLVs that are transacted by the TLV nodes.
1 — Originator
Indicates the Isilon string that is used as originator. This string enables the OS10 switches to easily identify the
Isilon originated LLDP PDUs.
2 — RA Prex Indicates the IPV6 address prex for SLAAC. This prex is also used by Isilon nodes to communicate with the
master and the OS10 switch to compute the Virtual IP address for the specic fabric instance. The RA prex is
dierent for each fabric.
3 — Fabric ID Indicates the ID of the fabric the LLDP PDU is originating from.
These are the sub-types used in LLDP custom TLVs that are transacted by the OS10 switches.
1 — Originator
Indicates the OS10 string that is used as originator. The string enables the OS10 switches to easily identify LLDP
PDUs.
Layer 2 193