Users Guide

Table Of Contents
3. Create an NVE instance and configure a Loopback interface as the VXLAN source tunnel interface.
OS10(config)# nve
OS10(config-nve)# source-interface loopback 1
4. Specify the NSX controller reachability information.
OS10(config-nve)# controller ovsdb
OS10(config-nve-ovsdb)# ip 10.16.140.182 port 6640 ssl
OS10(config-nve-ovsdb)# max-backoff 10000
OS10(config-nve-ovsdb)# exit
5. Assign interfaces to be managed by the controller.
OS10(config)# interface ethernet 1/1/25:3
OS10(config-if-eth1/1/25:3)# switchport mode trunk
OS10(config-if-eth1/1/25:3)# no switchport access vlan
OS10(config-if-eth1/1/25:3)# nve-controller
6. (Optional) Enable BFD.
OS10(config)# bfd enable
Verify the controller configuration
VTEP 1
To view controller-based information on the VTEP 1, use the show nve controller command.
OS10# show nve controller
Management IP : 10.16.140.11/16
Gateway IP : 200.0.0.1
Max Backoff : 10000
Configured Controller : 10.16.140.181:6640 ssl (connected)
Controller Cluster
IP Port Protocol Connected State Max-Backoff
10.16.140.182 6640 ssl true ACTIVE 10000
10.16.140.183 6640 ssl true ACTIVE 10000
10.16.140.181 6640 ssl true ACTIVE 10000
NVE Controller Ports
ethernet1/1/54:3
To display the VNID, port members, source interface, and remote VTEPs of the VXLAN, use the show virtual-network
command.
OS10# show virtual-network
Codes: DP - MAC-learn Dataplane, CP - MAC-learn Controlplane, UUD - Unknown-Unicast-Drop
Virtual Network: 0
Members:
Virtual Network: 6000
Members:
VLAN 20: ethernet1/1/54:3
VxLAN Virtual Network Identifier: 6000
Source Interface: loopback1(200.0.0.1)
Remote-VTEPs (flood-list): 13.0.0.5(CP)
To view all the replicators and their status in the VXLAN, use the show nve replicators command.
OS10# show nve replicators
Codes: * - Active Replicator
BFD Status:Disabled
Replicators State
VXLAN
1097