Specifications

Table Of Contents
Trac is sent from the CPU internally generated packet to the front-end SFP+ ports which are connected with the Dell EMC SFP+ optics
using a cable.
Connect the rst port to IXIA and all other ports with Loopback optics.
nputool -i -t 5 -T ixia_self -d
nputool --init --test 5 --traffic ixia_self -d
Congure the VLAN and display the BCM.0> shell. To verify the counters, use the show c command in the BCM shell.
IXIA trac with adjacent ports connected to IXIA
Trac is sent from the CPU internally generated packet to the front-end ports which are connected with DACs or optics using cables
connected top-to-bottom.
Connect two ports to IXIA with SFP+ optics and cables.
nputool -i -t 5 -T ixia_adj
nputool --init --test 5 --traffic ixia_adj
Congure the VLAN and display the BCM.0> shell. To verify the counters, use the show c command in the BCM shell.
PRBS for QSFP ports
Connect ports with Loopback cables and run the PRBS MAC and EXT Loopback tests.
PRBS MAC level test nputool –i –t 2 or nputool --init --test 2
PRBS EXT level test nputool –i –t 3 or nputool --init --test 3
For example:
root@dell-diag-os:~# nputool --init --test 2 DMA pool size: 16777216 PCI unit 0: Dev 0x8375,
Rev 0x11, Chip BCM88375_B0,
Driver BCM88375_B0 sysconf_probe successful global_sal_config successful ***
1 BCM devices are detected Diag NPU initialization over
Test link_status_test for NPU 0 ................ SKIPPED <<<---
Test snake_traffic_test for NPU 0 .............. SKIPPED <<<---
Test prbs_mac_test for NPU 0 ................... Passed
Test prbs_ext_test for NPU 0 ................... SKIPPED <<<---
Test uplink_link_status_test for NPU 0 ......... SKIPPED <<<---
Test uplink_snake_traffic_test for NPU 0 ....... SKIPPED <<<---
Test uplink_prbs_mac_test for NPU 0 ............ SKIPPED <<<---
Test uplink_prbs_ext_test for NPU 0 ............ SKIPPED <<<---
NPU tests ...................................... Passed
root@dell-diag-os:~# nputool --init --test 3 DMA pool size: 16777216 PCI unit 0: Dev 0x8375,
Rev 0x11, Chip BCM88375_B0,
Driver BCM88375_B0 sysconf_probe successful global_sal_config successful ***
1 BCM devices are detected Diag NPU initialization over
Test link_status_test for NPU 0 ................ SKIPPED <<<---
Test snake_traffic_test for NPU 0 .............. SKIPPED <<<---
Test prbs_mac_test for NPU 0 ................... SKIPPED <<<---
Test prbs_ext_test for NPU 0 ................... Passed
Test uplink_link_status_test for NPU 0 ......... SKIPPED <<<---
Test uplink_snake_traffic_test for NPU 0 ....... SKIPPED <<<---
Test uplink_prbs_mac_test for NPU 0 ............ SKIPPED <<<---
Test uplink_prbs_ext_test for NPU 0 ........... SKIPPED <<<---
NPU tests ...................................... Passed
PRBS for uplink ports
54
Dell EMC DiagOS tools