Reference Guide

Table Of Contents
iscsi target port
Configures the TCP ports used to monitor iSCSI sessions with target storage devices.
Syntax
iscsi target port tcp-port1 [tcp-port2, ..., tcp-port16] [ip-address ip-
address]
Parameters
tcp-port Enter one or more TCP port numbers (0 to 65535). Separate TCP port numbers with a
comma.
ip-address ip-address (Optional) Enter the IP address in A.B.C.D format of a storage array
whose iSCSI traffic is monitored on the TCP port.
Default 3260,860
Command Mode CONFIGURATION
Usage
Information
You can configure up to 16 TCP ports to monitor iSCSI traffic from target storage devices. The no
version of this command including the IP address removes a TCP port from iSCSI monitoring.
Example
OS10(config)# iscsi target port 26,40
Supported
Releases
10.3.0E or later
lldp tlv-select dcbxp-appln iscsi
Enables a port to advertise iSCSI application TLVs to DCBX peers.
Syntax
lldp tlv-select dcbxp-appln iscsi
Parameter None
Default iSCSI application TLVs are advertised to DCBX peers.
Command Mode INTERFACE
Usage
Information
DCB devices use DCBX to exchange iSCSI configuration information with peers and self-configure. iSCSI
parameters are exchanged in time, length, and value (TLV) messages. DCBX requires LLDP enabled
to advertise iSCSI application TLVs. iSCSI application TLVs advertise the PFC dot1p priority-bitmap
configured with the iscsi priority-bits command to DCBX peers. If you do not configure an
iSCSI dot1p-bitmap value, iSCSI application TLVs advertise dot1p 4 by default only if you configure dot1p
4 as a PFC priority with the pfc-cos command. The no version of this command disables iSCSI TLV
transmission.
Example
OS10(conf-if-eth1/1/1)# lldp tlv-select dcbxp-appln iscsi
Supported
Releases
10.3.0E or later
show iscsi
Displays currently configured iSCSI settings.
Syntax
show iscsi
Parameters None
Command Mode EXEC
Usage
Information
This command output displays global iSCSI configuration settings. Use the show iscsi session
command to view target and initiator information.
Example
OS10# show iscsi
iSCSI Auto configuration is Enabled
730 Converged data center services