Users Guide

Table Of Contents
Example
OS10(config)# switch-operating-mode Full-Switch
Supported
releases
10.4.3.0 or later
gnmi-security-profile
Set the security profile for the gNMI agent.
Syntax
gnmi-security-profile profile-name
Parameters profile-name Enter the name of the security profile to be associated with the gNMI agent.
Default Not configured
Command mode CONFIGURATION
Usage
information
Before establishing a connection to the gNMI agent, set a valid application-specific security profile for the
gNMI agent. Also, configure a FQDN or an IP address for entry to the SmartFabric Director server, assign
client and CA certificates, and assign the syatem Admin privileges to the user role that is used to access
the agent. The security profile is configured on the switch using the crypto security-profile
command.
Example
os10(config)# gnmi-security-profile gnmi_sec_profile
Supported
releases
10.5.0.1 or later
show switch-operating-mode
View the operating mode of the switch.
Syntax
show switch-operating-mode
Parameters None
Default Not configured
Command mode EXEC
Usage
information
Some OS10 switches operate in both Full Switch and SmartFabric modes. For PowerEdge MX Ethernet
I/O modules, see Dell EMC PowerEdge MX Networking Deployment Guide. This command is updated to
display the SmartFabric Director operating mode starting in release 10.5.0.1.
Example
OS10# show switch-operating-mode
Switch-Operating-Mode : SmartFabric Director Mode
Supported
releases
10.4.0E(R3S) or later
show sfd status
Displays the status corresponding to the SmartFabric Director.
Syntax
show sfd status
Default Display the controller IP address and the port status of the SmartFabric Director.
Command mode EXEC
Usage
information
None.
SmartFabric Director 143