Concept Guide

Table Of Contents
Command Mode CONFIGURATION
Usage
Information
Use this command to configure or update the VLTi information after SFS is enabled on the switch. The
system reloads with the configured VLTi ports.
This command can be used only if the switch should already be in L3 fabric mode. If not, enable the L3
fabric personality first and run this command.
If you use any of the existing ports for the VLTi, those ports should also be specified as part of the VLTi
configuration using the SmartFabric Services commands.
Example
OS10(config)#smartfabric vlti ethernet 1/1/31-1/1/32
Warning:The system will be reloaded now, for the personality changes to
take effect
Supported
Releases
10.5.0.3 or later
show logging smartfabric
Displays important logs that are related to SFS modules.
NOTE: You must have access to sysadmin, secadmin, or netadmin roles to run this command.
Syntax
show logging smartfabric
Parameters <1-65535>Number of recent messages to be displayed.
Default Not applicable
Command Mode EXEC
Usage
Information
You can run this command on all switches in SmartFabric mode and are provided with a high-level view
of the events happening in the SFS module. When you run this command on an active switch, the system
displays complete cluster-related logs. The logs include events that are related to cluster formation and
update, configuration changes, and on boarding events along with switch-specific information. When you
run this command on a backup switch, the system displays only the switch-specific logs.
Example
MX9116N-B2# show logging smartfabric 100 | grep CAGT
2020-03-29 10:09:35.334 MX9116N-B2 [DNV-CAGT] [chassis.get_lead_chassis]
lead chassis not in chassis_data
2020-03-29 10:09:35.335 MX9116N-B2 [DNV-CAGT] [chassis.get_lead_chassis]
not receive mdns from lead MSM yet
2020-03-29 10:09:56.881 MX9116N-B2 [DNV-CAGT]
[app.process_cps_cluster_sync_event] received sync state 2
2020-03-29 10:09:56.881 MX9116N-B2 [DNV-CAGT] [ka.clr_priority]
2020-03-29 10:09:56.885 MX9116N-B2 [DNV-CAGT] [ka.set_priority] new 100
old 0
2020-03-29 10:09:58.014 MX9116N-B2 [DNV-CAGT] [ka.soft_reload_ka]
reloading ka...
Supported
Releases
10.5.2.1 or later
show smartfabric cluster
Displays the basic cluster information of the switch or IOM.
Syntax
show smartfabric cluster
Parameters None
44 SFS commands