Concept Guide
Table Of Contents
- Dell EMC SmartFabric Services User Guide Release 1.0
- About this guide
- SFS fundamentals
- Setting up SFS
- Deploying and managing a fabric
- Access fabric setup options
- Update default fabric, switch names, and descriptions
- Create uplink for external network connectivity
- Breakout switch ports
- Configure jump host
- Update network configuration
- Onboard a server onto the fabric
- Edit default fabric settings
- Restore fabric configuration
- Manage network profiles
- Manage routing profiles
- Access fabric setup options
- SFS with VxRail
- SFS with PowerEdge MX
- SFS for Isilon/PowerScale back-end fabric
- SFS commands
- smartfabric l3fabric enable
- smartfabric vlti
- show logging smartfabric
- show smartfabric cluster
- show smartfabric cluster member
- show smartfabric configured-server
- show smartfabric configured-server configured-server-interface
- show smartfabric details
- show smartfabric discovered-server
- show smartfabric discovered-server discovered-server-interface
- show smartfabric networks
- show smartfabric nodes
- show smartfabric personality
- show smartfabric uplinks
- show smartfabric upgrade-status
- show smartfabric validation-errors
- show switch-operating-mode
- Appendix
![](/manual/dell/powerswitch-s4248fb-on-s4248fbl-on/concept-guide-english/images/img-43.png)
Default None
Command Mode EXEC
Usage
Information
This command is supported in both Full Switch and SmartFabric modes.
Example (IOM)
MX9116N-A1# show smartfabric cluster
----------------------------------------------------------
CLUSTER DOMAIN ID : 119
VIP : fde1:53ba:e9a0:de14:0:5eff:fe00:1119
ROLE : BACKUP
SERVICE-TAG : 3GB1XC2
MASTER-IPV4 : 10.11.105.15
----------------------------------------------------------
Example (VxRail -
L2 fabric)
OS10# show smartfabric cluster
----------------------------------------------------------
CLUSTER DOMAIN ID : 100
VIP : fde2:53ba:e9a0:cccc:0:5eff:fe00:1100
ROLE : MASTER
SERVICE-TAG : B37HXC2
MASTER-IPV4 : 10.11.106.27
PREFERRED-MASTER :
----------------------------------------------------------
Example (VxRail -
L3 fabric)
OS10# show smartfabric cluster
----------------------------------------------------------
CLUSTER DOMAIN ID : 100
VIP : fde2:53ba:e9a0:cccc:0:5eff:fe00:1100
ROLE : MASTER
SERVICE-TAG : B37HXC2
MASTER-IPV4 : 10.11.106.27
PREFERRED-MASTER : true
----------------------------------------------------------
Supported
Releases
● MX9116n and MX5108n—10.5.0.1 or later
● SFS-supported OS10 switches—10.5.0.3 or later
show smartfabric cluster member
Displays information about the switch in a cluster. Information includes service tag, IP address, status, role, switch type and
chassis model, and chassis service tag where the switch is connected.
Syntax
show smartfabric cluster member
Parameters None
Default None
Command Mode EXEC
Usage
Information
When you run this command on a switch, the output that is displayed varies depending on the switch
role. For example, if you run this command on the master switch, the output shows both the master
and backup switch information. If you run this command on a backup switch, the output shows only the
master switch information.
This command is supported in both Full Switch and SFS modes.
Example (IOM)
MX9116N-A1# show smartfabric cluster member
Service-tag IP Address Status
Role Type Chassis-Service-Tag Chassis-Slot
SFS commands 45