Power supplies
The S4200-ON Series (S4248FB-ON and S4248FBL-ON) switch ships with two AC or DC power supplies.
The S4200-ON Series switch supports AC or DC power supplies with two air-flow directions, normal and reverse. Normal is from
the I/O to the PSU side. Reverse is from the PSU side to the I/O side. Two PSUs are required for full redundancy, but the
switch can operate with a single PSU.
The PSUs are field replaceable. When running with full redundancytwo power supplies installed and running, you can remove
and replace one PSU without disrupting traffic.
CAUTION: To prevent electrical shock, ensure that the S4200-ON Series switch is grounded properly. If you do
not ground your equipment correctly, excessive emissions may result. Use a qualified electrician to ensure that
the power cables meet your local electrical requirements.
NOTE: Connect the power supply to the appropriate branch circuit protection as defined by your local electrical codes and
verify that the remote power source complies with the switch input power specifications.
NOTE: If you use a single PSU, install a blank plate in the other PSU slot. Use power supply 2 (PSU2) as the blank plate
slot. To install the blank plate, use a #1 Philips screw driver.
NOTE: ESD damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap
when handling the S4200-ON Series switch and its components.
Topics:
Components
AC or DC power supply installation
Connect DC power supply to power source
Components
The following power supply options are available for the S4200-ON Series (S4248FB-ON and S4248FBL-ON) switch:
AC or DC power supply with integrated fan
AC or DC power supply with integrated reverse flow fan
Power supply 1 (PSU1) is on the left side of the switch; power supply 2 (PSU2) is on the right side of the switch.
Figure 16. S4200-ON Series PSUs
1. PSUs
The PSUs have an integrated fan, which you cannot replace individually; if the fans integrated in a PSU fail, you must replace
the entire PSU. However, you can replace the fan trays individually. For fan tray replacement procedures, see Fans.