Reference Guide
2. Check air flow through the system. Ensure that the air ducts are clean and that all fans are working correctly.
3. After the software has determined that the temperature levels are within normal limits, you can re-power the card
safely. To bring back the line card online, use the power-on command in EXEC mode.
In addition, to control airflow for adequate system cooling, Dell Networking requires that you install blanks in all slots
without a line card.
NOTE: Exercise care when removing a card; if it has exceeded the major or shutdown thresholds, the card could
be hot to the touch.
Recognize an Under-Voltage Condition
If the system detects an under-voltage condition, it sends an alarm.
To recognize this condition, look for the following system message: %CHMGR-1-CARD_SHUTDOWN: Major
alarm: Line card 2 down - auto-shutdown due to under voltage
.
This message indicates that the specified card is not receiving enough power. In response, the system first shuts down
Power over Ethernet (PoE). If the under-voltage condition persists, line cards are shut down, then the RPMs.
Troubleshoot an Under-Voltage Condition
To troubleshoot an under-voltage condition, check that the correct number of power supplies are installed and their
Status light emitting diodes (LEDs) are lit.
The following table lists information for SNMP traps and OIDs on S-Series environmental monitoring hardware and
hardware components.
Table 78. SNMP Traps and OIDs
OID String OID Name Description
Receiving Power
.1.3.6.1.4.1.6027.3.10.1.2.5.1.6 chSysPortXfpRecvPower OID displays the receiving power of
the connected optics.
Transmitting power
.1.3.6.1.4.1.6027.3.10.1.2.5.1.8 chSysPortXfpTxPower OID displays the transmitting power of
the connected optics.
Temperature
.1.3.6.1.4.1.6027.3.10.1.2.5.1.7 chSysPortXfpRecvTemp OID displays the temperature of the
connected optics.
NOTE: These OIDs only generate
if you enable the enable
optic-info-update-
interval is enabled
command.
Hardware MIB Buffer Statistics
.1.3.6.1.4.1.6027.3.16.1.1.4 fpPacketBufferTable View the modular packet buffers
details per stack unit and the mode of
allocation.
904