Users Guide
------------------------------------------------
 Failover Count: 0
 Last failover timestamp: None
 Last failover Reason: None
 Last failover type: None
-- Last Data Block Sync Record: --
------------------------------------------------
 stack-unit Config: succeeded Nov 25 2014 15:29:58
 Start-up Config: succeeded Nov 25 2014 15:29:58
 Runtime Event Log: succeeded Nov 25 2014 15:29:58
 Running Config: succeeded Nov 25 2014 15:29:58
 ACL Mgr: succeeded Nov 25 2014 15:29:58
 LACP: no block sync done
 STP: no block sync done
 SPAN: no block sync done
Management Access on S-Series Stacks
You can access the stack via the console port or VTY line.
• Console access — You may access the stack through the console port of the master unit (stack manager) only. Similar to a 
standby RPM, the console port of the standby unit does not provide management capability; only a limited number of commands 
are available. Member units provide a limited set of commands.
• Remote access — You may access the master unit and standby unit in a stack through the dedicated management Ethernet 
interfaces with SNMP, SSH, or via Telnet.
Example of Accessing Non-Master Units on a Stack via the Console Port
-----------------CONSOLE ACCESS ON A STANDBY----------------------------
Dell(standby)#?
cd Change current directory
clear Reset functions
copy Copy from one file to another
delete Delete a file
dir List files on a filesystem
disable Turn off privileged commands
enable Turn on privileged commands
exit Exit from the EXEC
format Format a filesystem
fsck Filesystem check utility
pwd Display current working directory
rename Rename a file
reset Reset selected card
show Show running system information
ssh-peer-stack-unit Open a SSH connection to the peer stack-unit
start Start shell
telnet-peer-stack-unit Open a telnet connection to the peer stack-unit
terminal Set terminal line parameters
upload Upload file
Dell(standby)#
-----------------CONSOLE ACCESS ON A MEMBER----------------------------
Stack(stack-member-0)#?
reset-self Reset this unit alone
show Show running system information
You can connect two units with two or more stacking cables in case of a stacking port or cable failure. Removal of only one of the 
cables does not trigger a reset.
Important Points to Remember
• You may stack up to six S4820T systems.
• The S4820T cannot be stacked with other system types.
814
Stacking