Reference Guide

threshold
Specify the minimum and maximum threshold values for the configured WRED profiles.
S4820T
Syntax
threshold min number max number
To remove the threshold values, use the no threshold min number max number
command.
Parameters
min
number
Enter the keyword min then the minimum threshold number for the
WRED profile. The range is from 1024KB to 77824KB.
max
number
Enter the keyword max then the maximum threshold number for the
WRED profile. The range is from 1024KB to 77824KB.
Defaults none
Command Modes CONFIGURATION (config-wred)
Command History
This guide is platform-specific. For command information about other platforms, refer to the
relevant
FTOS Command Line Reference Guide
.
The following is a list of the FTOS version history for this command.
Version 8.3.19.0 Introduced on the S4820T.
Version 8.3.11.1 Introduced on the Z9000.
Version 8.3.8.0 Introduced on the S4810.
pre-Version
6.1.1.1
Introduced on the E-Series.
Usage
Information
To configure the minimum and maximum threshold values for user-defined profiles, use this
command. Additionally, to modify the minimum and maximum threshold values for the pre-
defined WRED profiles, use this command. If you delete the threshold values of the pre-defined
WRED profiles, the profiles revert to their original default values.
Pre-Defined WRED Profile Name Minimum Threshold Maximum Threshold
wred_drop 0 0
wred_ge_y 1024 2048
wred_ge_g 2048 4096
wred_teng_y 4096 8192
wred_teng_g 8192 16384
Related
Commands
wred-profile — creates a WRED profile.
1132