Reference Guide
Related 
Commands
show snmp user — displays the information configured on each SNMP user name.
snmp-server view
Configure an SNMPv3 view.
S4820T
Syntax
snmp-server view view-name oid-tree {included | excluded}
To remove an SNMPv3 view, use the no snmp-server view view-name oid-tree 
{included | excluded} command.
Parameters
view-name
Enter the name of the view (not to exceed 20 characters).
oid-tree
Enter the OID sub tree for the view (not to exceed 20 characters).
included (OPTIONAL) Enter the keyword included to include the MIB family 
in the view.
excluded (OPTIONAL) Enter the keyword excluded to exclude the MIB family 
in the view.
Defaults none
Command Modes CONFIGURATION
Command History
This guide is platform-specific. For command information about other platforms, refer to the 
relevant 
FTOS Command Line Reference Guide
.
The following is a list of the FTOS version history for this command.
Version 8.3.19.0 Introduced on the S4820T.
Version 8.3.11.1 Introduced on the Z9000.
Version 8.3.7.0 Introduced on the S4810.
Version 7.6.1.0 Introduced on the S-Series.
Version 7.5.1.0 Introduced on the C-Series.
E-Series legacy 
command
Usage 
Information
The oid-tree variable is a full sub-tree starting from 1.3.6 and cannot specify the name of a 
sub-tree or a MIB. The following Example configures a view named 
rview
 that allows access to 
all objects under 1.3.6.1.
Example
FTOS# conf
FTOS#(conf) snmp-server view rview 1.3.6.1 included
Related 
Commands
show running-config snmp — displays the SNMP running configuration.
1292