Reference Guide
ethernet cfm mep
Create an MEP.
S4820T
Syntax
ethernet cfm mep {up-mep | down-mep} domain {name | level} ma-
name name mepid mep-id
Parameters
[up-mep | down-
mep]
Specify whether the MEP is up or down facing.
• Up-MEP: monitors the forwarding path internal to a bridge on
the customer or provider edge; on Dell Networking systems,
the internal forwarding path is effectively the switch fabric
and forwarding engine.
• Down-MEP: monitors the forwarding path external to another
bridge.
domain [
name
|
level
]
Enter the keyword domain and then enter the domain name or
domain level.
ma-name
name
Enter the keyword ma-name and then enter the name of the
maintenance association.
mepid
mep-id
Enter an MEP ID. The range is from 1 to 8191.
Defaults none
Command Modes INTERFACE
Command History
This guide is platform-specific. For command information about other platforms, refer to the
relevant
FTOS Command Line Reference Guide
.
The following is a list of the FTOS version history for this command.
Version 8.3.19.0 Introduced on the S4820T.
Version 8.3.11.1 Introduced on the Z9000.
Version 8.3.7.0 Introduced on the S4810.
Version 8.3.1.0 Introduced on the S-Series.
ethernet cfm mip
Create a maintenance intermediate point (MIP).
S4820T
Syntax
ethernet cfm mip domain {name | level} ma-name name
145