Reference Guide
Version 8.1.1.0 Introduced on the E-Series ExaScale.
Version 7.6.1.0 Introduced on the S-Series.
Version 7.5.1.0 Introduced on the C-Series.
pre-Version 
6.1.1.0
Introduced on the E-Series.
Example (Single 
Range)
This example shows how to define an interface range macro named test. Execute the show 
running-config command to display the macro definition.
FTOS(config)# define interface-range test 
tengigabitethernet0/0-3,
gigabitethernet 5/0-47, gigabitethernet 13/0-89
FTOS# show running-config | grep define
define interface-range test tengigabitethernet0/0-3, 
gigabitethernet5/0-47,
gigabitethernet 13/0 - 89
FTOS(config)#interface range macro test
FTOS(config-if-range-te-0/0-3,gi-5/0-47,gi-13/0-89)#
Related 
Commands
interface range – configures a range of command (bulk configuration)
interface range macro name – runs an interface range macro.
interface range macro name
Run the interface-range macro to automatically configure the pre-defined range of interfaces.
S4820T
Syntax
interface range macro name
Parameters
name
Enter the name of an existing macro.
Defaults none
Command Modes CONFIGURATION
Command History
This guide is platform-specific. For command information about other platforms, refer to the 
relevant 
FTOS Command Line Reference Guide
.
The following is a list of the FTOS version history for this command.
Version 8.3.19.0 Introduced on the S4820T.
Version 8.3.11.1 Introduced on the Z9000.
Version 8.3.7.0 Introduced on the S4810.
Version 8.1.1.0 Introduced on the E-Series ExaScale.
Version 7.6.1.0 Introduced on the S-Series.
Version 7.5.1.0 Introduced on the C-Series.
Version 6.2.1.0 Introduced
581