Reference Guide

Version 8.3.16.0 Introduced on MXL 10/40GbE Switch IO Module.
Example
FTOS# show isci session
Session 0:
------------------------------------------------------
Target: iqn.2001-05.com.equallogic:
0-8a0906-0e70c2002-10a0018426a48c94-iom010
Initiator: iqn.1991-05.com.microsoft:win-x9l8v27yajg
ISID: 400001370000
Session 1:
---------------------------------------------------------
Target: iqn.2001-05.com.equallogic:
0-8a0906-0f60c2002-0360018428d48c94-iom011
Initiator: iqn.1991-05.com.microsoft:win-x9l8v27yajg
ISID: 400001370000.
Usage
Information
Only sessions the switch observes are learned; sessions flowing through an adjacent switch
are not learned.
After the switch is reloaded, any information exchanged during the initial handshake is not
available. If the switch picks up the communication after reloading, it would detect a session
was in progress but could not obtain complete information for it. Any incomplete information of
this type would not be available in the show commands.
Related
Commands
show iscsi — displays the currently configured iSCSI settings.
show iscsi session detailed — displays detailed information about active iSCSI
sessions on the switch.
show run iscsi — shows run iscsi.
show iscsi session detailed
Display detailed information on active iSCSI sessions on the switch.
S4820T
Syntax
show iscsi session detailed [session isid]
Parameters
isid
Enter the session’s iSCSi ID to display detailed information about the
specified iSCSi session.
Command Modes
EXEC
EXEC Privilege
Command History
This guide is platform-specific. For command information about other platforms, refer to the
relevant
FTOS Command Line Reference Guide
.
The following is a list of the FTOS version history for this command.
751