Reference Guide

4
Control and Monitoring
This chapter contains the commands to configure and monitor the system, including Telnet, file transfer protocol (FTP),
and trivial file transfer protocol (TFTP) as they apply to the following Dell Networking S4820T platform.
NOTE: This command replaces the enable optic-info-update interval command to update
information on temperature and power monitoring in the simple network management protocol (SNMP)
management information base (MIB).
asf-mode
Enable alternate store and forward (ASF) mode and forward packets as soon as a threshold is reached.
S4820T
Syntax
asf-mode stack-unit {unit-id | all} queue size
To return to standard Store and Forward mode, use the no asf-mode stack unit
command.
Parameters
unit-id Enter the stack member unit identifier of the stack member to reset.
The S4820T range is from 0 to 11.
NOTE: The S4820T commands accept Unit ID numbers from 0 to
11, though S4820T supports stacking of up to six units with FTOS
version 8.3.12.0.
queue size Enter the queue size of the stack member. The range is from 0 to 15.
Defaults Not configured
Command Modes CONFIGURATION
Command History
This guide is platform-specific. For command information about other platforms, refer to the
relevant
FTOS Command Line Reference Guide
.
The following is a list of the FTOS version history for this command.
Version 8.3.19.0 Introduced on the S4820T.
Version 8.3.11.0 Introduced on the Z9000.
Version 8.3.7.0 Introduced on the S4810.
79