Reference Guide

Example
FTOS#sho is traffic
IS-IS: Level-1 Hellos (sent/rcvd) : 0/721
IS-IS: Level-2 Hellos (sent/rcvd) : 900/943
IS-IS: PTP Hellos (sent/rcvd) : 0/0
IS-IS: Level-1 LSPs sourced (new/refresh) : 0/0
IS-IS: Level-2 LSPs sourced (new/refresh) : 1/3
IS-IS: Level-1 LSPs flooded (sent/rcvd) : 0/0
IS-IS: Level-2 LSPs flooded (sent/rcvd) : 5934/5217
IS-IS: Level-1 LSPs CSNPs (sent/rcvd) : 0/0
IS-IS: Level-2 LSPs CSNPs (sent/rcvd) : 472/238
IS-IS: Level-1 LSPs PSNPs (sent/rcvd) : 0/0
IS-IS: Level-2 LSPs PSNPs (sent/rcvd) : 10/337
IS-IS: Level-1 DR Elections : 4
IS-IS: Level-2 DR Elections : 4
IS-IS: Level-1 SPF Calculations : 0
IS-IS: Level-2 SPF Calculations : 389
IS-IS: LSP checksum errors received : 0
IS-IS: LSP authentication failures : 0
FTOS#
spf-interval
Specify the minimum interval between shortest path first (SPF) calculations.
S4820T
Syntax
spf-interval [level-l | level-2] interval seconds
[initial_wait_interval seconds [second_wait_interval seconds]]
To restore default values, use the no spf-interval [level-l | level-2]
interval seconds [initial_wait_interval seconds
[second_wait_interval seconds]] command.
Parameters
level-l (OPTIONAL) Enter the keyword level-1 to apply the configuration
to Level-1 SPF calculations.
level-2 (OPTIONAL) Enter the keyword level-2 to apply the configuration
to Level-2 SPF calculations.
interval seconds
Enter the maximum number of seconds between SPF calculations.
The range is from 0 to 120 seconds. The default is 10 seconds.
initial_wait_interv
al seconds
(OPTIONAL) Enter the initial wait time, in seconds, before running the
first SPF calculations. The range is from 0 to 120 seconds. The default
is 5 seconds.
second_wait_inte
rval seconds
(OPTIONAL) Enter the wait interval, in seconds, between the first and
second SPF calculations. The range is from 0 to 120 seconds. The
default is 5 seconds.
Defaults Refer to
Parameters
.
812