Users Guide
• For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet then the slot/port information.
• For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the
slot/port information.
Defaults All interfaces in Layer 2 mode are untagged.
Command Modes INTERFACE VLAN
Command History
This guide is platform-specic. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.5.1.0 Added support for 4-port 40G line cards on ExaScale.
8.3.7.0 Introduced on the S4810.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
pre-6.2.1.1 Introduced on the E-Series.
Usage Information
Untagged interfaces can only belong to one VLAN.
In the Default VLAN, you cannot use the no untagged interface command. To remove an untagged
interface from all VLANs, including the Default VLAN, enter INTERFACE mode and use the no
switchport
command.
Related Commands
interface vlan — congures a VLAN.
tagged — species which interfaces in a VLAN are tagged.
Far-End Failure Detection (FEFD)
The Dell Networking operating software supports far-end failure detection (FEFD) on the Ethernet interfaces of the S4820T
platform.
The FEFD feature detects and reports far-end link failures.
• FEFD is not supported on the Management interface.
1008