Users Guide
Version Description
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the S4810.
8.3.11.1 Introduced on the Z9000.
8.1.1.0 Introduced on the E-Series ExaScale.
7.7.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
7.4.1.0 Introduced on the E-Series.
Usage Information The monitoring command is saved in the running conguration at the Monitor Session mode level and
can be restored after a chassis reload.
Example
Dell# show running-config monitor session
!
monitor session 1
source TenGigabitEthernet 1/1 destination TenGigabitEthernet 1/2 direction
rx
!
monitor multicast-queue 7
Related Commands
monitor session — creates a monitoring session.
show monitor session — displays a monitoring session.
source (port monitoring)
Congure a port monitor source.
Syntax
source {interface | range | any} destination interface direction {rx | tx |
both}
To disable a monitor source, use the no source interface destination interface
direction {rx | tx | both} command.
Parameters
source interface Enter one of the following keywords and slot/port information:
• For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet then the slot/port information.
• For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the
slot/port information.
•
For a VLAN interface enter the keyword VLAN followed by a number from 1 to
4094.
• For a port channel interface, enter the keywords port-channel then a
number.
range Enter the keyword range to specify the list of interfaces.
any Enter the keyword any to specify all interfaces.
Port Monitoring