Reference Guide

Control and Monitoring | 101
Example
(E-Series)
FTOS#show chassis brief
Chassis Type : E1200
Chassis Mode : TeraScale
Chassis Epoch : 3.2 micro-seconds
-- Line cards --
Slot Status NxtBoot ReqTyp CurTyp Version Ports
---------------------------------------------------------------------------
0 not present
1 not present
2 not present
3 not present
4 not present
5 not present
6 not present
7 not present
8 not present
9 not present
10 not present
11 online online E48PF E48PF 6.1.1.0 48
12 not present E48PF
13 not present E48PF
-- Route Processor Modules --
Slot Status NxtBoot Version
---------------------------------------------------------------------------
0 active online 6.1.1.0
1 not present
Switch Fabric State: up
-- Switch Fabric Modules --
Slot Status
---------------------------------------------------------------------------
0 active
1 active
2 active
3 active
4 active
5 active
6 active
7 active
8 active
-- Power Entry Modules --
Bay Status
---------------------------------------------------------------------------
0 up
1 up
-- Fan Status --
Tray Status Temp Volt Speed PEM0 PEM1 Fan1 Fan2 Fan3
------------------------------------------------------------------------------
0 up < 50C 12-16V low/2100-2700 RPM up up up up up
1 up < 50C 12-16V low/2100-2700 RPM up up up up up
2 up < 50C 12-16V low/2100-2700 RPM up up up up up
3 up < 50C 12-16V low/2100-2700 RPM up up up up up
4 up < 50C 16-20V med/2700-3200 RPM up up up up up
5 up < 50C 12-16V low/2100-2700 RPM up up up up up