Reference Guide
Control and Monitoring | 101
Example
(E-Series)
FTOS#show chassis brief
Chassis Type : E1200
Chassis Mode : TeraScale
Chassis Epoch : 3.2 micro-seconds
-- Line cards --
Slot Status NxtBoot ReqTyp CurTyp Version Ports
---------------------------------------------------------------------------
 0 not present
 1 not present
 2 not present
 3 not present
 4 not present
 5 not present
 6 not present
 7 not present
 8 not present
 9 not present
 10 not present
 11 online online E48PF E48PF 6.1.1.0 48
 12 not present E48PF
 13 not present E48PF
-- Route Processor Modules --
Slot Status NxtBoot Version
---------------------------------------------------------------------------
 0 active online 6.1.1.0
 1 not present
Switch Fabric State: up
-- Switch Fabric Modules --
Slot Status
---------------------------------------------------------------------------
 0 active
 1 active
 2 active
 3 active
 4 active
 5 active
 6 active
 7 active
 8 active
-- Power Entry Modules --
Bay Status
---------------------------------------------------------------------------
 0 up
 1 up
-- Fan Status --
Tray Status Temp Volt Speed  PEM0 PEM1 Fan1 Fan2 Fan3
------------------------------------------------------------------------------
 0 up < 50C 12-16V low/2100-2700 RPM up up up up up
 1 up < 50C 12-16V low/2100-2700 RPM up up up up up
 2 up < 50C 12-16V low/2100-2700 RPM up up up up up
 3 up < 50C 12-16V low/2100-2700 RPM up up up up up
 4 up < 50C 16-20V med/2700-3200 RPM up up up up up
 5 up < 50C 12-16V low/2100-2700 RPM up up up up up
Related
Commands
show linecard View line card status
show rpm View Route Processor Module status.
show sfm View Switch Fabric Module status.










