Reference Guide
1098 | Open Shortest Path First (OSPFv2)
www.dell.com | support.dell.com
Defaults
No MD5 authentication is configured.
Command Modes
INTERFACE
Command
History
Usage
Information
To change to a different key on the interface, enable the new key while the old key is
still enabled. The FTOS will send two packets: the first packet authenticated with the
old key, and the second packet authenticated with the new key. This process ensures
that the neighbors learn the new key and communication is not disrupted by keeping
the old key enabled.
After the reply is received and the new key is authenticated, you must delete the old
key. Dell Force10 recommends keeping only one key per interface.
ip ospf mtu-ignore
c e s
Disable OSPF MTU mismatch detection upon receipt of database description (DBD)
packets.
Syntax
ip ospf mtu-ignore
To return to the default, enter no ip ospf mtu-ignore.
Defaults
Enabled
Command Modes
INTERFACE
Command
History
ip ospf network
c e s
Set the network type for the interface.
Version 8.3.19.0 Introduced on S4820T
Version 8.3.7.0 Introduced on S4810
Version 7.6.1.0 Introduced on S-Series
Version 7.5.1.0 Introduced on C-Series
pre-Version 6.1.1.1 Introduced on E-Series
Note: The MD5 secret is stored as plain text in the configuration file with service
password encryption.
Version 8.3.19.0 Introduced on S4820T
Version 8.3.7.0 Introduced on S4810
Version 7.6.1.0 Introduced on S-Series
Version 7.5.1.0 Introduced on C-Series
pre-Version 6.1.1.1 Introduced on E-Series