Reference Guide

110 | Control and Monitoring
www.dell.com | support.dell.com
Usage
Information
The show inventory media command provides some details about installed pluggable
media (SFP, XFP), as shown in the Example (show inventory media). Use the
show
interfaces
command to get more details about installed pluggable media.
The display output might include a double asterisk (**) next to the SFMs, for
example:
...
0 CC-E-SFM ** 0004875 7490007411 A
1 CC-E-SFM ** 0004889 7490007411 A
...
The double asterisk generally indicates the SFM’s frequency capabilities, indicating
either that they are operating at 125 MHz or that the frequency capability, which is
stored in an EPROM, cannot be determined.
If there are no fiber ports in the line card, then just the header under show inventory
media will be displayed. If there are fiber ports but no optics inserted, then the output
will display "Media not present or accessible".
Example
(C300)
FTOS# show inventory
Chassis Type : C300
Chassis Mode : 1.0
Software Version : FTOS-EF-7.6.1.0
Slot Item Serial Number Part Number Revision
--------------------------------------------------------------
C300 TY000001400 7520029999 04
3 LC-CB-GE-48T FX000020075 7520036700 01
0 LC-CB-RPM 0060361 7520029300 02
0 CC-C-1200W-AC N/A N/A N/A
1 CC-C-1200W-AC N/A N/A N/A
0 CC-C300-FAN
* - standby
Software Protocol Configured
--------------------------------------------------------------
OSPF
FTOS#
Example
(E-Series)
FTOS# show inventory
Chassis Type : E300
Chassis Mode : TeraScale
Software Version : FTOS-EF-7.5.1.0
Slot Item Serial Number Part Number Revision
--------------------------------------------------------------
E300 0015259 7520009601 02
1 LC-EF3-10GE-2P 0017259 7520012501 01
2 LC-EF3-GE-48T 0017269 7520009702 01
3 LC-EF3-1GE-24P 0031151 7520014206 04
Version 6.2.1.0 Expanded to include Software Protocol Configured field on E-Series
Version 5.3.1.0 Introduced on E-Series