Reference Guide
114 | Control and Monitoring
www.dell.com | support.dell.com
Example
(C-Series)
FTOS#show linecard 11
-- Line card 11 --
Status : online
Next Boot : online
Required Type : E48PF - 48-port GE line card with SFP optics (EF)
Current Type : E48PF - 48-port GE line card with SFP optics (EF)
Hardware Rev : Base - 1.0 PP0 - n/a PP1 - n/a
Num Ports : 48
Up Time : 12 hr, 37 min
FTOS Version : 6.2.1.x
Jumbo Capable : yes
Boot Flash : A: 2.0.3.4 B: 2.0.3.4 [booted]
Memory Size : 268435456 bytes
Temperature : 49C
Power Status : PEM0: absent or down PEM1: up
Voltage : ok
Serial Number :
Part Number : Rev
Vendor Id :
Date Code :
Country Code :
FTOS#
Example
(show linecard
brief)
FTOS#show linecard 11 brief
-- Line card 11 --
Status : online
Next Boot : online
Required Type : E48PF - 48-port GE line card with SFP optics (EF)
Current Type : E48PF - 48-port GE line card with SFP optics (EF)
Hardware Rev : Base - 1.0 PP0 - n/a PP1 - n/a
Num Ports : 48
Up Time : 11 hr, 24 min
FTOS Version : 6.1.1.0
Jumbo Capable : yes
FTOS#
Table 4-1 list the definitions of the fields shown in the examples.
Table 4-1. Descriptions for show linecard output
Field Description
Line card Displays the line card slot number (only listed in
show linecard all
command output).
Status Displays the line card’s status.
Next Boot Displays whether the line card is to be brought online at the next
system reload.
Required Type Displays the line card type configured for the slot.
The Required Type and Current Type must match. Use the
linecard command to reconfigure the line card type if they do not
match.
Current Type Displays the line card type installed in the slot.
The Required Type and Current Type must match. Use the
linecard command to reconfigure the line card type if they do not
match.
Hardware Rev Displays the chip set revision.