Reference Guide

Control and Monitoring | 139
Command Modes
EXEC
EXEC Privilege
Command
History
Usage
The second example shows the output from the show system brief command.
The last example shows the output from the
show system stack-unit command.
Example
(show system)
FTOS#show system
Stack MAC : 00:01:e8:8b:3e:42
Reload-Type : normal-reload [Next boot : normal-reload]
-- Unit 0 --
Unit Type : Management Unit
Status : online
Next Boot : online
Required Type : S4810 - 52-port GE/TE/FG (SE)
Current Type : S4810 - 52-port GE/TE/FG (SE)
Master priority : 0
Hardware Rev : 3.0
Num Ports : 64
Up Time : 3 hr, 7 min
FTOS Version : 4810-8-3-7-1667
Jumbo Capable : yes
POE Capable : no
FIPS Mode : disabled
Stack MAC : 00:01:e8:8b:3e:42
Reload-Type : normal-reload [Next boot : normal-reload]
-- Unit 0 --
Unit Type : Management Unit
Status : online
Next Boot : online
Required Type : S4810 - 52-port GE/TE/FG (SE)
Current Type : S4810 - 52-port GE/TE/FG (SE)
Master priority : 0
Hardware Rev : 3.0
Num Ports : 64
Up Time : 3 hr, 7 min
FTOS Version : 4810-8-3-7-1667
Jumbo Capable : yes
POE Capable : no
FIPS Mode : disabled
Burned In MAC : 00:01:e8:8b:3e:42
No Of MACs : 3
-- Power Supplies --
Unit Bay Status Type FanStatus
----------------------------------------------------------------------------
0 0 up AC up
0 1 absent absent
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
----------------------------------------------------------------------------
Version 7.8.1.0 Modified output: Boot Flash field will display code level for boot code 2.8.1.1
and newer, while older boot codes are displayed as “Present”
Version 7.7.1.0 Modified output: Added Master Priority field.
Version 7.6.1.0 Introduced for S-Series switches