Reference Guide
sFlow | 1399
Defaults
Not configured
Command Modes
CONFIGURATION
Command
History
Usage
Information
You can configure up to two sFlow collectors (IPv4 or IPv6). If two collectors are 
configured, traffic samples are sent to both.
The sFlow agent address is carried in a field in SFlow packets and is used by the 
collector to identify the sFlow agent.
IPv6 sFlow collectors and agents are supported on E-Series (ExaScale and 
TeraScale), C-Series, and S-Series routers.
To delete a configured collector, enter the 
no sflow collector {ipv4-address | 
ipv6-address} agent-addr {ipv4-address | ipv6-address} [number [max-datagram-size 
number]] | [max-datagram-size number] command. 
As part of the sFlow-MIB, if the SNMP request originates from a configured 
collector, FTOS will return the corresponding configured agent IP in MIB requests. 
FTOS checks to ensure that two entries are not configured for the same collector IP 
with a different agent IP. Should that happen, FTOS generates the following error:
%Error: Different agent-addr attempted for an existing collector
number 
(OPTIONAL) Enter the UDP port number (User Datagram 
Protocol).
Range: 0 to 65535
Default: 6343
max-datagram-size number
(OPTIONAL) Enter the keyword max-datagram-size 
followed by the size number in bytes. 
Range: 400 to 1500
Default: 1400
Version 8.3.19.0 Introduced on S4820T
Version 8.4.2.3 Support for IPv6 sFlow collectors and agents was added on the E-series 
TeraScale, C-Series, and S-Series.
Version 8.4.1.1 Support for IPv6 sFlow collectors and agents was added on the E-series 
ExaScale.
Version 8.3.7.0 Introduced on S4810 
Version 8.2.1.0 Introduces on S-Series Stacking
Version 8.1.1.0 Introduced on E-Series ExaScale
Version 7.7.1.0 Introduced on S-Series
Version 7.6.1.0 Introduced on C-Series
Version 6.5.1.0 Expanded the no form of the command to mirror the syntax used to configure
Version 6.2.1.1 Introduced on E-Series