Reference Guide
Control and Monitoring | 141
Example
(show system
stack-unit)
FTOS#show system stack-unit 0
-- Unit 0 --
Unit Type : Management Unit
Status : online 
Next Boot : online 
Required Type : S50V - 48-port E/FE/GE with POE (SB)
Current Type : S50V - 48-port E/FE/GE with POE (SB)
Master Priority : 4 
Hardware Rev : 2.0 
Num Ports : 52 
Up Time : 3 hr, 17 min
FTOS Version : 7.6.1.0a 
Jumbo Capable : yes 
POE Capable : no 
Boot Flash : Present 
Memory Size : 254701568 bytes
Temperature : 43C 
Voltage : ok
Serial Number : DZ267160000
Part Number : 7590003600 Rev B
Vendor Id : 07 
Date Code : 12172007
Country Code : 01 
Burned In MAC : 00:01:e8:cc:cc:cc 
No Of MACs : 3
--Module 0--
Status : online 
Module Type : S50-01-10GE-2P - 2-port 10GE XFP (SB)
Num Ports : 2
Hot Pluggable : no
-- Module 1 -
Status : online
Module Type : S50-01-10GE-2C - 2-port 10GE CX4 (SB)
Num Ports : 2
Hot Pluggable : no
- Power Supplies --
Unit Bay Status Type
---------------------------------------------------------------------------
 0 0 up AC
 0 1 absent
-- Fan Status --
------------------------------------------------------------------------------
Unit TrayStatus Fan0 Fan1 Fan2 Fan3 Fan4 Fan5
 0 up up up up up up up
FTOS#
Related
Commands
show version Display the FTOS version.
show processes memory 
(S-Series)
Display memory usage based on running processes. 
show system stack-ports Display information about the stack ports on all switches in the 
S-Series stack.