Reference Guide
1444 | S-Series Stacking Commands
www.dell.com | support.dell.com
Commands
The commands in this chapter are used for managing the stacking of S-Series
systems:
• redundancy disable-auto-reboot
• redundancy force-failover stack-unit
• reset stack-unit
• show redundancy
• show system stack-ports
• stack-unit priority
• stack-unit provision
• stack-unit renumber
• stack-unit stack-group
• upgrade system stack-unit (S-Series stack member)
redundancy disable-auto-reboot
s
Prevent the S-Series stack management unit, stack member unit, and standby unit
from rebooting if they fail.
Syntax
redundancy disable-auto-reboot [members | 0-11]
To return to the default, enter no redundancy disable-auto-reboot stack-unit.
The stack-unit range is 0-11.
Defaults
Disabled (the failed switch is automatically rebooted).
Command Modes
CONFIGURATION
Command
History
Usage
Information
Enabling this command keeps the failed switch in the failed state. It will not reboot
until it is manually rebooted. When enabled, it is not displayed in the running-config.
When disabled, it is displayed in the running-config.
Related
Commands
redundancy force-failover stack-unit
s
Force the standby unit in the stack to become the management unit.
Version 8.3.1.0 Added the members option
Version 7.7.1.0 Introduced on S-Series
show redundancy Display the current redundancy status.