Reference Guide
1446 | S-Series Stacking Commands
www.dell.com | support.dell.com
Related
Commands
show redundancy
s
Display the current redundancy configuration (status of automatic reboot
configuration on stack management unit).
Syntax
show redundancy
Command Modes
EXEC
EXEC Privilege
Command
History
Example
FTOS#show redundancy
FTOS#show redundancy
-- SSeries Redundancy Configuration --
------------------------------------------------
Auto reboot : Enabled
-- Stack-unit Status --
------------------------------------------------
Mgmt ID: 0
Stack-unit ID: 0
Stack-unit Redundancy Role: Primary
Stack-unit State: Active
Stack-unit SW Version: 7.7.1.0
Link to Peer: Up
-- PEER Stack-unit Status --
------------------------------------------------
Stack-unit State: Standby
Peer stack-unit ID: 1
Stack-unit SW Version: 7.7.1.0
-- Stack-unit Redundancy Configuration --
------------------------------------------------
Primary Stack-unit: mgmt-id 0
Auto Data Sync: Full
Failover Type: Hot Failover
Auto reboot Stack-unit: Enabled
Auto failover limit: 3 times in 60 minutes
-- Stack-unit Failover Record --
------------------------------------------------
Failover Count: 0
Last failover timestamp: None
Last failover Reason: None
Last failover type: None
-- Last Data Block Sync Record: --
------------------------------------------------
reload Reboot FTOS.
upgrade (S-Series management unit
and Z9000)
Reset the designated S-Series stack member.
Version 7.7.1.0 Introduced on S-Series