Reference Guide
Uplink Failure Detection (UFD) | 1501
Defaults
The auto-recovery of UFD-disabled downstream ports is enabled.
Command Modes
UPLINK-STATE-GROUP
Command
History
Usage
Information
To disable auto-recovery on downstream links, enter the no downstream auto-recover 
command.
Related
Commands
downstream disable links 
s S50 only
Configure the number of downstream links in the uplink-state group that will be 
disabled if one upstream link in an uplink-state group goes down.
Syntax
downstream disable links {number |all}
Parameters
Defaults
No downstream links are disabled when an upstream link in an uplink-state group 
goes down. 
Command Modes
UPLINK-STATE-GROUP
Command
History
Usage
Information
A user-configurable number of downstream interfaces in an uplink-state group are 
put into a link-down state with an UFD-Disabled error message when one upstream 
interface in an uplink-state group goes down.
If all upstream interfaces in an uplink-state group go down, all downstream interfaces 
in the same uplink-state group are put into a link-down state. 
To revert to the default setting, enter the 
no downstream disable links command.
Version 8.3.19.0 Introduced on S4820T
Version 8.3.12.0 Introduced on S4810
Version 8.4.2.3 Introduced on the S-Series S50.
downstream Assign a port or port-channel to the uplink-state group as a downstream 
interface.
uplink-state-group Create an uplink-state group and enabling the tracking of upstream 
links.
number Enter the number of downstream links to be brought down by UFD. 
Range: 1 to 1024.
all Brings down all downstream links in the group. 
Version 8.3.19.0 Introduced on S4820T
Version 8.3.12.0 Introduced on S4810
Version 8.4.2.3 Introduced on the S-Series S50.










