Reference Guide

GARP VLAN Registration (GVRP) | 557
garp timers
c e s
Set the intervals (in milliseconds) for sending GARP messages.
Syntax
garp timers {join | leave | leave-all}
To return to the previous setting, use the
no garp timers {join | leave | leave-all}
command.
Parameters
Defaults
Default as above
Command Modes
CONFIGURATION-GVRP
Command
History
Usage
Information
Join Timer—Join messages announce the willingness to register some attributes with
other participants. Each GARP application entity sends a Join message twice, for
reliability, and uses a join timer to set the sending interval.
Leave Timer—Leave announces the willingness to de-register with other participants.
Together with the Join, Leave messages help GARP participants complete attribute
reregistration and de-registration. Leave Timer starts upon receipt of a leave message
sent for de-registering some attribute information. If a join message is not received before
the leave time expires, the GARP application entity removes the attribute information as
requested.
Leave All Timer—The Leave All Timer starts when a GARP application entity starts.
When this timer expires, the entity sends a leave-all message so that other entities can
re-register their attribute information. Then, the leave-all time begins again.
join
Enter the keyword join followed by the number of milliseconds to configure the join
time.
Range: 100 to 147483647 milliseconds
Default: 200 milliseconds
Note: Designate the milliseconds in multiples of 100
leave
Enter the keyword leave followed by the number of milliseconds to configure the leave
time.
Range: 100 to 2147483647 milliseconds
Default: 600 milliseconds
Note: Designate the milliseconds in multiples of 100
leave-all
Enter the keyword leave-all followed by the number of milliseconds to configure the
leave-all time.
Range: 100 to 2147483647 milliseconds
Default: 1000 milliseconds
Note: Designate the milliseconds in multiples of 100
Version 8.3.19.0 Introduced on S4820T
Version 8.3.7.0 Introduced on S4810
Version 7.6.1.0 Introduced on C, E, and S-Series