Example
(show sfm all)
FTOS#show sfm all
Switch Fabric State: up
-- Switch Fabric Modules --
Slot Status
---------------------------------------------------------------------------
 0 active
 1 active
 2 active
 3 active
 4 active
 5 active
 6 active
 7 active
 8 active
FTOS#
show startup-config
c e s
Display the startup configuration.
Syntax
show startup-config
Command Modes
EXEC Privilege
Command
History
Example
FTOS#show startup-config
Table 3-2. show sfm Command Output Fields
Field Description
Switch Fabric State: States that the Switch Fabric is up (8 SFMs are online and operating).
Status Displays the SFM’s active status.
Card Type States the type of SFM.
Up Time Displays the number of hours and minutes since the RPM’s last reboot.
Temperature Displays the temperature of the RPM. 
Minor alarm status if temperature is over 65° C.
Power Status Displays power status: absent, down, or up
Serial Num Displays the line card serial number.
Part Num Displays the line card part number.
Vendor ID Displays an internal code, which specifies the manufacturing vendor.
Date Code Displays the line card’s manufacturing date.
Country Code Displays the country of origin.
01 = USA
Version 7.6.1.0 Introduced on S-Series
Version 7.5.1.0 Introduced on C-Series
Version 7.4.1.0 Expanded to include last configuration change and start-up last updated (date 