Reference Guide

High Availability (HA) | 567
Parameters
Defaults
By default, a process can be restarted a maximum of 3 times within 1 hour. On the
exception that exceeds this limit, the system reloads or fails over.
Command Modes
CONFIGURATION
Command
History
Related
Commands
redundancy auto-failover-limit
c e
Specify an auto-failover limit for RPMs. When an non-recoverable fatal error is
detected, an automatic RPM failover occurs. This command does not affect
user-initiated (manual) failovers.
Syntax
redundancy auto-failover-limit
[count number [period minutes] | period minutes]]
To disable the auto-failover limit control, enter
no redundancy auto-failover-limit.
Parameters
Defaults
Count: 3 Period: 60 minutes
Command Modes
CONFIGURATION
Command
History
process
Configure a process to be restartable.
count
number
Enter the number of times a process can restart within the configured
period.
Range: 1-3
Default: 3
period
minutes
Enter the amount of time within which the process can restart count times.
Range: 1-60 minutes
Default: 60 minutes
Version 8.3.19.0 Introduced on the S4820T.
Version 8.3.12.0 Introduced on the S4810.
Version 8.4.1.0 Introduced on E-Series.
show processes restartable
count number Enter the number of times the RPMs can automatically failover within the
period defined in the period parameter.
Range: 2 to 10
Default: 3
period minutes] Enter a duration in which to allow a number of automatic failovers (limited to
the number defined in the count parameter).
Range: 5 to 9000 minutes
Default: 60 minutes
Version 8.1.1.0 Introduced on E-Series ExaScale
Version 7.5.1.0 Introduced on C-Series
Version 7.6.1.0 Introduced on E-Series