Reference Guide

610 | Interfaces
www.dell.com | support.dell.com
Changes in the flow-control values may not be reflected automatically in the show interface
output. As a workaround, apply the new settings, execute
shut followed by no shut on the
interface, and then check the running-config of the port using the
show interface command.
Important Points to Remember
Do not enable tx pause when buffer carving is enabled. Consult Dell Force10
TAC for information and assistance.
Asymmetric flow control (
rx on tx off or rx off tx on) setting for the interface port
less than 100 Mb/s speed is not permitted. The following error is returned:
Can’t configure Asymmetric flowcontrol when speed <1G, config
ignored
The only configuration applicable to half duplex ports is rx off tx off. The
following error is returned:
Can’t configure flowcontrol when half duplex is configure, config
ignored
Half duplex cannot be configured when the flow control configuration is on
(default is
rx on tx on). The following error is returned:
Can’t configure half duplex when flowcontrol is on, config ignored
Speeds less than 1 Gig cannot be configured when the asymmetric flow control
configuration is on. The following error is returned:
Can’t configure speed <1G when Asymmetric flowcontrol is on, config
ignored
FTOS only supports rx on tx on and rx off tx off for speeds less than 1 Gig
(Symmetric).
On the C-Series and S-Series systems, the flow-control sender and receiver must
be on the same port-pipe. Flow control is not supported across different
port-pipes on the C-Series or S-Series system.
Example
FTOS(conf-if-gi-0/1)#show config
!
interface GigabitEthernet 0/1
no ip address
switchport
no negotiation auto
flowcontrol rx off tx on
no shutdown
...
Note: If rx flow control is disabled, Dell Force10 recommends rebooting the system.
Note: The flow control must be off (rx off tx off) before configuring the half duplex.