Reference Guide
610 | Interfaces
www.dell.com | support.dell.com
Changes in the flow-control values may not be reflected automatically in the show interface 
output. As a workaround, apply the new settings, execute 
shut followed by no shut on the 
interface, and then check the running-config of the port using the 
show interface command. 
Important Points to Remember
• Do not enable tx pause when buffer carving is enabled. Consult Dell Force10 
TAC for information and assistance.
• Asymmetric flow control (
rx on tx off or rx off tx on) setting for the interface port 
less than 100 Mb/s speed is not permitted. The following error is returned:
Can’t configure Asymmetric flowcontrol when speed <1G, config 
ignored
• The only configuration applicable to half duplex ports is rx off tx off. The 
following error is returned:
Can’t configure flowcontrol when half duplex is configure, config 
ignored
• Half duplex cannot be configured when the flow control configuration is on 
(default is 
rx on tx on). The following error is returned:
Can’t configure half duplex when flowcontrol is on, config ignored 
• Speeds less than 1 Gig cannot be configured when the asymmetric flow control 
configuration is on. The following error is returned:
Can’t configure speed <1G when Asymmetric flowcontrol is on, config 
ignored
• FTOS only supports rx on tx on and rx off tx off for speeds less than 1 Gig 
(Symmetric).
• On the C-Series and S-Series systems, the flow-control sender and receiver must 
be on the same port-pipe. Flow control is not supported across different 
port-pipes on the C-Series or S-Series system.
Example
FTOS(conf-if-gi-0/1)#show config
!
interface GigabitEthernet 0/1
no ip address
switchport
no negotiation auto
flowcontrol rx off tx on
no shutdown
...
Note: If rx flow control is disabled, Dell Force10 recommends rebooting the system. 
Note: The flow control must be off (rx off tx off) before configuring the half duplex.