Reference Guide
632 | Interfaces
www.dell.com | support.dell.com
Parameters
Command Modes
EXEC
EXEC Privilege
Command
History
Usage
Information
Use this show interfaces command for details on a specific interface. Use the show interfaces 
linecard
 command for details on all interfaces on the designated line card.
Note that, in an E-Series EtherScale chassis, the 
show interfaces command output does not 
include details about installed SFP or XFP transceivers.
On the S4810, the show interface output displays incorrect rate information details over time 
for link monitoring when the rate-interval is configured for 5 seconds. Dell Force10 
recommends using higher rate-intervals such as 15 to 299 seconds to minimize the errors 
interface
Enter one of the following keywords and slot/port or number information:
• For a Fast Ethernet interface, enter the keyword 
FastEthernet followed by the 
slot/port information.
• For a 1-Gigabit Ethernet interface, enter the keyword 
GigabitEthernet followed 
by the slot/port information. 
• For a Loopback interface, enter the keyword 
loopback followed by a number 
from 0 to 16383.
• For the management interface on an RPM, enter the keyword 
ManagementEthernet followed by the slot/port information. The slot range is 0 
to 1 and the port range is 0. 
• For a Null interface, enter the keywords 
null 0.
• For a Port Channel interface, enter the keyword 
port-channel followed by a 
number:
C-Series and S-Series Range: 1 to 128
E-Series Range: 1 to 32 for EtherScale, 1 to 255 for TeraScale and 1 to 512 for 
ExaScale. 
• For a SONET interface, enter the keyword 
sonet followed by the slot/port. 
• For a 10-Gigabit Ethernet interface, enter the keyword 
TenGigabitEthernet 
followed by the slot/port information. 
• For a 40-Gigabit Ethernet interface, enter the keyword 
fortyGigE followed by the 
slot/port information.
• For a VLAN interface, enter the keyword 
vlan followed by a number from 1 to 4094.
Version 8.3.19.0 Introduced on S4820T 
Version 8.5.1.0 Added support for 4-port 40G line cards on ExaScale.
Version 8.3.7.0 Introduced on S4810 
Version 8.2.1.2 Include SFP and SFP+ optics power detail in E-Series and C-Series output.
Version 8.2.1.0 Support for 4093 VLANs on E-Series ExaScale. Prior releases supported 2094.
Version 8.1.1.0 Introduced on E-Series ExaScale
Version 7.8.1.0 Output expanded to include SFP+ media in C-Series
Version 7.6.1.0  Introduced on S-Series
Version 7.5.1.0  Introduced on C-Series
Version 6.4.1.0 Changed organization of display output
Version 6.3.1.0 Added Pluggable Media Type field in E-Series TeraScale output