Reference Guide
Interfaces | 661
Parameters
Defaults
Not configured.
Command Modes
INTERFACE PORTCHANNEL
Command
History
Usage
Information
Use the interface port-channel command to access this command.
You cannot add an interface to a Port Channel if the interface contains an IP address in its
configuration. Only the shutdown, description, mtu, and ip mtu commands can be configured
on an interface if it is to be added to a Port Channel. The mtu and ip mtu commands are only
available when the chassis is in Jumbo mode.
Link MTU and IP MTU considerations for Port Channels are:
• All members must have the same link MTU value and the same IP MTU value.
• The Port Channel link MTU and IP MTU must be less than or equal to the link
MTU and IP MTU values configured on the channel members.
Example: If the members have a link MTU of 2100 and an IP MTU 2000, the Port Channel’s
MTU values cannot be higher than 2100 for link MTU or 2000 bytes for IP MTU.
When an interface is removed from a Port Channel with the no channel-member command
syntax, the interface reverts to its configuration prior to joining the Port Channel.
An interface can belong to only one Port Channel.
interface
Enter the following keywords and slot/port or number information:
• For a 100/1000 Ethernet interface, enter the keyword
GigabitEthernet
followed by the slot/port information.
• For a Gigabit Ethernet interface, enter the keyword
GigabitEthernet followed
by the slot/port information.
• For a SONET interface, enter the keyword
sonet followed by the slot/port
information.
• For a Ten Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet
followed by the slot/port information.
• For a 40-Gigabit Ethernet interface, enter the keyword
fortyGigE followed by
the slot/port information.
version 8.3.19.0 Introduced on S4820T
Version 8.5.1.0 Added support for 4-port 40G line cards on ExaScale.
version 8.3.7.0 Introduced on S4810
Version 8.1.1.0 Introduced on E-Series ExaScale
Version 7.6.1.0 Introduced on S-Series
Version 7.5.1.0 Introduced on C-Series
pre-Version 6.2.1.0 Introduced for E-Series