Reference Guide
Control and Monitoring | 69
Parameters
Defaults
Not configured.
Command Modes
CONFIGURATION
Command
History
Usage
Information
You must save the configuration and reload the system to implement ASF. When you 
enter the command, the system sends a message stating that the new mode is enabled 
when the system reloads.
audible cut-off
e
Turn off an audible alarm.
Syntax
audible cut-off
Defaults
Not configured.
Command Modes
EXEC Privilege
banner exec
c e s
Configure a message that is displayed when a user enters the EXEC mode.
Syntax
banner exec c line c
Parameters
Defaults
No banner is displayed.
Command Modes
CONFIGURATION
unit-id Enter the stack member unit identifier of the stack member to reset. 
S4810 and S4820T range: 0 - 11
Z9000 range: 0 - 7
all 
Note: The S4810 and S4820T commands accept Unit ID numbers 0-11, though 
S4810 and the S4820T support stacking up to 6 units with FTOS version 8.3.12.0.
queue size Enter the queue size of the stack member.
Range: 0 - 15
Version 8.3.19.0 Introduced on the S4820T
Version 8.3.11.0 Introduced on the Z9000
Version 8.3.7.0 Introduced on the S4810
c  Enter the keywords banner exec, and then enter a character delineator, 
represented here by the letter c, and press ENTER. 
line Enter a text string for your banner message ending the message with your 
delineator.
In the example below, the delineator is a percent character (%); the banner 
message is “testing, testing”.