Reference Guide

Control and Monitoring | 95
The following table provides descriptions for the status response symbols displayed
in output.
power-off
c e
Turn off power to a selected line card or the standby (extra) Switch Fabric Module
(SFM).
Syntax
power-off {linecard number | sfm sfm-slot-id}
Parameters
Defaults
Disabled
Command Modes
EXEC Privilege
Command
History
Related
Commands
power-on
c e
Turn on power to a line card or the standby (extra) Switch Fabric Module (SFM).
Table 1 ping command Status Response Symbols and Descriptions
Symbol Description
!
Each exclamation point indicates receipt of a reply
.
Each period indicates the network server timed out while waiting for a reply
U
A destination unreachable error PDU was received
Q
Source quench (destination too busy)
M
Could not fragment
?
Unknown packet type
&
Packet lifetime exceeded
linecard number Enter the keyword linecard and a number for the line card slot number.
C-Series Range: 0-7
E-Series Range: 0 to 13 on a E1200/E1200i, 0 to 6 on a E600/E600i, and 0
to 5 on a E300.
sfm sfm-slot-id Enter the keyword sfm by the slot number of the SFM to which you want to
turn off power.
Note: This option is supported on E-Series only.
Version 8.1.1.2 Introduced on E-Series ExaScale E600i
Version 8.1.1.0 Introduced on E-Series ExaScale E1200i
Version 7.5.1.0 Introduced on C-Series
E-Series original Command
power-on Power on a line card or standby SFM.