Reference Guide
Control and Monitoring | 99
service timestamps 
c e s
Add time stamps to debug and log messages. This command adds either the uptime or 
the current time and date.
Syntax
service timestamps [debug | log] [datetime [localtime] [msec] [show-timezone] | 
uptime]
Parameters
Defaults
Not configured.
Command Modes
CONFIGURATION
Command
History
Usage
Information
If you do not specify parameters and enter service timestamps, it appears as service 
timestamps debug uptime 
in the running-configuration.
Use the show running-config command to view the current options set for the service 
timestamps command.
show alarms 
c e s
View alarms for the RPM, SFMs, line cards and fan trays.
Syntax
show alarms [threshold]
Parameters
debug
(OPTIONAL) Enter the keyword debug to add timestamps to debug 
messages.
log
(OPTIONAL) Enter the keyword log to add timestamps to log messages 
with severity 0 to 6.
datetime
(OPTIONAL) Enter the keyword datetime to have the current time and date 
added to the message.
localtime
(OPTIONAL) Enter the keyword localtime to include the localtime in the 
timestamp.
msec
(OPTIONAL) Enter the keyword msec to include milliseconds in the 
timestamp.
show-timezone (OPTIONAL) Enter the keyword 
show-timezone to include the time zone 
information in the timestamp.
uptime
(OPTIONAL) Enter the keyword uptime to have the timestamp based on 
time elapsed since system reboot.
Version 8.1.1.0 Introduced on E-Series ExaScale
Version 7.6.1.0 Introduced on S-Series
Version 7.5.1.0 Introduced on C-Series
E-Series original Command
threshold
(OPTIONAL) Enter the keyword threshold to display the temperature thresholds 
set for the line cards, RPM, and SFMs.