Users Guide
NOTE: Although, each port on the S4810, S4820T, and S5000 devices support 8 QoS queues, you can congure only 4
QoS queues (0-3) to manage data trac. The remaining 4 queues (4-7) are reserved for control trac.
Dell(conf)#do show qos dot1p-queue-mapping
Dot1p Priority : 0 1 2 3 4 5 6 7
Queue : 0 0 0 1 2 3 3 3
Dell(conf)#
The conguration of no-drop queues provides exibility for ports on which PFC is not needed but lossless trac should egress from
the interface.
Lossless trac egresses out the no-drop queues. Ingress dot1p trac from PFC-enabled interfaces is automatically mapped to the
no-drop egress queues.
1. Enter INTERFACE Conguration mode.
CONFIGURATION mode
interface type slot/port
2. Congure the port queues that will still function as no-drop queues for lossless trac.
INTERFACE mode
pfc no-drop queues queue-range
For the dot1p-queue assignments, refer to the dot1p Priority-Queue Assignment table.
The maximum number of lossless queues globally supported on the switch is two.
The range is from 0 to 3. Separate the queue values with a comma; specify a priority range with a dash; for example, pfc no-
drop queues 1,3
or pfc no-drop queues 2-3.
The default: No lossless queues are congured.
NOTE: Dell Networking OS Behavior: By default, no lossless queues are congured on a port.
A limit of two lossless queues is supported on a port. If the amount of priority trac that you congure to be paused exceeds the
two lossless queues, an error message displays.
Conguring PFC in a DCB Map
An S4820T switch supports the use of a DCB map in which you congure priority-based ow control (PFC) setting. To congure
PFC parameters, you must apply a DCB map on an S4820T interface. This functionality is supported on the S4820T platform.
PFC Conguration Notes
PFC provides ow control based on the 802.1p priorities in a converged Ethernet trac that is received on an interface and is
enabled by default when you enable DCB. As an enhancement to the existing Ethernet pause functionality, PFC stops trac
transmission for specied priorities (CoS values) without impacting other priority classes. Dierent trac types are assigned to
dierent priority classes.
When trac congestion occurs, PFC sends a pause frame to a peer device with the CoS priority values of the trac that needs to
be stopped. DCBx provides the link-level exchange of PFC parameters between peer devices. PFC allows network administrators to
create zero-loss links for SAN trac that requires no-drop service, while at the same time retaining packet-drop congestion
management for LAN trac.
On switch, PFC is enabled by default on Ethernet ports (pfc mode on command). You can congure PFC parameters using a
DCB map or the
pfc priority command in Interface conguration mode. For more information, see Conguring Priority-Based
Flow Control.
Data Center Bridging (DCB)
245










