diagS4810DumpPowerGoodStatus[653]: ERROR: Psu : 0 Output voltage is NOT in regulation range
Test 1.000 - Psu Power Good Test .................................... FAIL
Test 1.001 - Psu Power Good Test .................................... PASS
Test 1 - Psu Power Good Test ....................................... FAIL
diagS4820DumpPsuStatus[1753]: ERROR: Psu0: Reporting fault in Current, Voltage and Fan
condition
diagS4820DumpPsuStatus[1757]: ERROR: Psu0: Output voltage is NOT in regulation range
Test 2.000 - Fan Psu Status test .................................... FAIL
Test 2.001 - Fan Psu Status test .................................... PASS
Test 2 - Fan Psu Status Test ....................................... FAIL
Test 3.000 - Fan board presence Test ................................ PASS
Test 3.001 - Fan board presence Test ................................ PASS
Test 3 - Fan Board Presence Test ................................... PASS
Test 4.000 - Board Fan Status Test .................................. PASS
Test 4.001 - Board Fan Status Test .................................. PASS
Test 4.002 - Board Fan Status Test .................................. PASS
Test 4.003 - Board Fan Status Test .................................. PASS
Test 4 - Board Fan Status Test ..................................... PASS
Test 5 - Fan Tray Air Flow Status Test ............................. PASS
Test 6.000 - TMP75A-CPU ............................................. PASS
Test 6.001 - TMP75B-MAC ............................................. PASS
Test 6.002 - TMP75C-LEFT-PHY ........................................ PASS
Test 6.003 - TMP75D-RIGHT-PHY ....................................... PASS
Test 6 - Temp Sensor Access Test .................................... PASS
Test 7 - RTC Presence Test .......................................... PASS
Test 8 - SDRAM Presence Test ........................................ PASS
Trace Logs
In addition to the syslog buer, Dell Networking OS buers trace messages which are continuously written by various Dell
Networking OS software tasks to report hardware and software events and status information.
Each trace message provides the date, time, and name of the Dell Networking OS process. All messages are stored in a ring buer.
You can save the messages to a le either manually or automatically after failover.
Auto Save on Crash or Rollover
Exception information for MASTER or standby units is stored in the ash:/TRACE_LOG_DIR directory. This directory contains les
that save trace information when there has been a task crash or timeout.
On a MASTER unit, you can reach the TRACE_LOG_DIR les by FTP or by using the show file command from the ash://
TRACE_LOG_DIR directory.
On a Standby unit, you can reach the TRACE_LOG_DIR les only by using the show file command from the ash://
TRACE_LOG_DIR
directory.
NOTE: Non-management member units do not support this functionality.
Last Restart Reason
If the system restarts for some reason (automatically or manually), the show system command output includes the reason for the
restart.
The following table shows the reasons displayed in the output and their corresponding causes.
Table 109. Line Card Restart Causes and Reasons
Causes Displayed Reasons
Remote power cycle of the chassis push button reset
reload soft reset
reboot after a crash soft reset