Reference Guide
2. Check air flow through the system. Ensure that the air ducts are clean and that all fans are working 
correctly.
3. After the software has determined that the temperature levels are within normal limits, you can re-
power the card safely. To bring back the line card online, use the power-on command in EXEC 
mode.
In addition, to control airflow for adequate system cooling, Dell Networking requires that you install 
blanks in all slots without a line card.
NOTE: Exercise care when removing a card; if it has exceeded the major or shutdown thresholds, 
the card could be hot to the touch.
Recognize an Under-Voltage Condition
If the system detects an under-voltage condition, it sends an alarm.
To recognize this condition, look for the following system message: %CHMGR-1-CARD_SHUTDOWN: 
Major alarm: Line card 2 down - auto-shutdown due to under voltage
.
This message indicates that the specified card is not receiving enough power. In response, the system 
first shuts down Power over Ethernet (PoE). If the under-voltage condition persists, line cards are shut 
down, then the RPMs.
Troubleshoot an Under-Voltage Condition
To troubleshoot an under-voltage condition, check that the correct number of power supplies are 
installed and their Status light emitting diodes (LEDs) are lit.
The following table lists information for SNMP traps and OIDs on S-Series environmental monitoring 
hardware and hardware components.
Table 81. SNMP Traps and OIDs
OID String OID Name Description
Receiving Power
.1.3.6.1.4.1.6027.3.10.1.2.5.1.6 chSysPortXfpRecvPower OID displays the receiving power 
of the connected optics.
Transmitting power
.1.3.6.1.4.1.6027.3.10.1.2.5.1.8 chSysPortXfpTxPower OID displays the transmitting 
power of the connected optics.
Temperature
.1.3.6.1.4.1.6027.3.10.1.2.5.1.7 chSysPortXfpRecvTemp OID displays the temperature of 
the connected optics.
NOTE: These OIDs only 
generate if you enable the 
enable optic-info-
update-interval is 
enabled command.
Hardware MIB Buffer Statistics
S-Series Debugging and Diagnostics
1071