Reference Guide
Warning - the stack unit will be pulled out of the stack for diagnostic
execution
Proceed with Diags [confirm yes/no]: yes
Warning - diagnostic execution will cause multiple link flaps on the peer side
- advisable
to shut directly connected ports
Proceed with Diags [confirm yes/no]: yes
Dell#00:03:13: %S25P:2 %DIAGAGT-6-DA_DIAG_STARTED: Starting diags on stack unit
2
00:03:13 : Approximate time to complete these Diags ... 6 Min
00:03:13 : Diagnostic test results will be stored on stack unit 2 file: flash:/
TestReport-SU-2.txt
Dell#00:03:35: %STKUNIT1-M:CP %CHMGR-2-STACKUNIT_DOWN: Stack unit 2 down - card
removed
00:08:50: %STKUNIT1-M:CP %CHMGR-5-STACKUNITDETECTED: Stack unit 2 present
00:09:00: %STKUNIT1-M:CP %CHMGR-5-CHECKIN: Checkin from Stack unit 2 (type
S25P, 28 ports)
00:09:00: %S25P:2 %CHMGR-0-PS_UP: Power supply 0 in unit 2 is up
00:09:00: %STKUNIT1-M:CP %CHMGR-5-STACKUNITUP: Stack unit 2 is up
[output from the console of the unit in which diagnostics are performed]
Dell(stack-member-2)#
Diagnostic test results are stored on file: flash:/TestReport-SU-2.txt
Diags completed... Rebooting the system now!!!
The following example shows the show file flash:\\ command (standalone member).
Dell#show file flash://TestReport-SU-0.txt
diagS4810UsbAOpen[735]: ERROR: Usb device open failed
*******************************S-Series Diagnostics***********************
Board : S4820T Dell Inc.
Stack Unit Board Serial Number : SWDG129100003
CPU Version : MPC8536E, Version: 1.1
CPLD REVISION : 0x9
CPLD BOARD TYPE : 0x9
Diag image based on build : 9-4(0-89)
Stack Unit Board temperature : 46 Degree C
Stack Unit Number : 0
**************************Stack Unit EEPROM INFO**************************
**************MFG INFO*******************
Data in Chassis Eeprom Mfg Info is listed as...
Vendor Id : 07
Country Code : 06
Date Code : 10222012
Serial Number : SWDG129100003
Part Number : 2P7Y5
Product Revision : A
Product Order Number : 02P7Y52BE0005A00123SBC902
**************************** S4820T LEVEL 0
DIAGNOSTICS**************************
diagS4810DumpPowerGoodStatus[653]: ERROR: Psu : 0 Output voltage is NOT in
regulation range
Test 1.000 - Psu Power Good Test .................................... FAIL
Test 1.001 - Psu Power Good Test .................................... PASS
Test 1 - Psu Power Good Test ....................................... FAIL
1066
S-Series Debugging and Diagnostics