Reference Guide

* This RPM -> 7.4.2.0
* Peer RPM -> 7.4.1.0
*
************************************************
00:00:12: %RPM0-U:CP %IRC-4-IRC_VERSION: Current RPM 7.4.2.0 Peer RPM 7.4.1.0 -
Different software version detected
00:00:12: %RPM0-U:CP %IRC-6-IRC_COMMUP: Link to peer RPM is up
00:00:14: %RPM0-U:CP %RAM-6-ELECTION_ROLE: RPM0 is transitioning to Primary RPM.
Example of Boot Failure on Standby RPM
System failed to boot up. Please reboot the chassis !!!
00:12:46: %RPM1-U:CP %TME-0-RPM BRINGUP FAIL: FTOS failed to bring up the system
Communication between RPMs is not up, check the software version and reboot
chassis.
Dell(standby)(bootfail)#
Automatic and Manual Stack Unit Failover
Stack unit failover is the process of the standby unit becoming a management unit.
Dell Networking OS fails over to the standby stack unit when:
1. Communication is lost between the standby and primary stack unit.
2. You request a failover via the CLI.
To display the reason for the last failover, use the show redundancy command from EXEC Privilege
mode.
Example of the show redundancy Command
Dell#show redundancy
-- RPM Status --
------------------------------------------------
RPM Slot ID: 0
RPM Redundancy Role: Primary
RPM State: Active
RPM SW Version: 7.6.1.0
Link to Peer: Up
-- PEER RPM Status --
------------------------------------------------
RPM State: Standby
RPM SW Version: 7.6.1.0
-- RPM Redundancy Configuration --
------------------------------------------------
Primary RPM: rpm0
Auto Data Sync: Full
Failover Type: Hot Failover
Auto reboot RPM: Enabled
Auto failover limit: 3 times in 60 minutes
-- RPM Failover Record --
------------------------------------------------
Failover Count: 0
Last failover timestamp: None
Last failover Reason: None
Last failover type: None
High Availability (HA)