Reference Guide
Field Description
• the parameter for auto failover limit control (the
redundancy auto-failover-limit command)
•
RPM Failover
Record
Displays the following information:
• RPM failover counter (to reset the counter, use the
redundancy reset-counter command)
• the time and date of the last RPM failover
• the reason for the last RPM failover
Last Data Sync
Record
Displays the data sync information and the timestamp for
the data sync:
• Start-up Config is the contents of the startup-config file.
• Line Card Config is the line card types configured and
interfaces on those line cards.
• Runtime Event Log is the contents of the Event log.
• Running Config is the current running-config.
This field only appears when you enter the command from
the Primary RPM.
Example
(S4820T)
Dell#show redundancy
-- Stack-unit Status --
------------------------------------------------
Mgmt ID: 0
Stack-unit ID: 0
Stack-unit Redundancy Role: Primary
Stack-unit State: Active
Stack-unit SW Version: FIT-R2D2-1-0-0-89
Link to Peer: Down
Peer Stack-unit: not present
-- Stack-unit Redundancy Configuration --
------------------------------------------------
Primary Stack-unit: mgmt-id 0
Auto Data Sync: Full
Failover Type: Hot Failover
Auto reboot Stack-unit: Disabled
Auto failover limit: 3 times in 60 minutes
-- Stack-unit Failover Record --
------------------------------------------------
Failover Count: 0
Last failover timestamp: None
Last failover Reason: None
Last failover type: None
-- Last Data Block Sync Record: --
------------------------------------------------
Stack Unit Config: no block sync done
Start-up Config: no block sync done
Runtime Event Log: no block sync done
Running Config: no block sync done
High Availability (HA)
707