Reference Guide
1 Success
2 Success
3 Not present
4 Not present
5 Not present
Power-cycling the unit(s).
Dell#
Example
(NvRAM, single
unit)
Dell#restore factory-defaults stack-unit 1nvram
**************************************************************
* Warning - Restoring factory defaults will delete the
existing *
* persistent settings (stacking, fanout, etc.) *
* After restoration the unit(s) will be powercycled
immediately. *
* Proceed with caution ! *
**************************************************************
Proceed with factory settings? Confirm [yes/no]:yes
-- Restore status --
Unit Nvram Config
------------------------
1 Success
Power-cycling the unit(s).
Dell#
show boot system
Displays information about boot images currently configured on the system.
S4820T
Syntax
show boot system {stack-unit {0-11 | 0-7 | 0-5 | all}}
Parameters
all Enter the keyword all to display the boot image information
for all line cards and rpms.
stack-unit Enter the keyword stack-unit followed by a number to
display boot image information for a stack-unit.
The S4820T range is from 0 to 11.
Defaults none
Command
Modes
• EXEC
• EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
74
File Management