Users Guide
Version Description
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
8.4.1.0 Introduced on the E-Series.
Related
Commands
• show processes restartable — display processes and tasks configured for restartability.
redundancy auto-failover-limit
Specify an auto-failover limit for RPMs. When a non-recoverable fatal error is detected, an automatic RPM failover occurs. This
command does not affect user-initiated (manual) failovers.
S4820T
Syntax
redundancy auto-failover-limit [count number [period minutes] | period
minutes]]
To disable the auto-failover limit control, use the no redundancy auto-failover-limit command.
Parameters
count number Enter the number of times the RPMs can automatically failover within the period
defined in the period parameter. The range is from 2 to 10. The default is 3.
period minutes Enter a duration in which to allow a number of automatic failovers (limited to the
number defined in the count parameter). The range is from 5 to 9000 minutes.
The default is 60 minutes.
Default
• Count: 3
• Period: 60 minutes
Command Modes CONFIGURATION
Command History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
Networking OS Command Line Reference Guide.
Version Description
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
8.1.1.0 Introduced on the E-Series.
7.5.1.0 Introduced on the C-Series.
7.6.1.0 Introduced on the E-Series
High Availability (HA) 642