Field Description
applied on the secondary RPM until failover occurs, and the routing table on
line cards is cleared during failover.
the status of auto booting the RPM (the redundancy disable-auto-
reboot command)
the parameter for auto failover limit control (the redundancy auto-
failover-limit command)
RPM Failover
Record
Displays the following information:
RPM failover counter (to reset the counter, use the redundancy reset-
counter command)
the time and date of the last RPM failover
the reason for the last RPM failover
Last Data Sync
Record
Displays the data sync information and the timestamp for the data sync:
Start-up Config is the contents of the startup-config file.
Line Card Config is the line card types configured and interfaces on those line
cards.
Runtime Event Log is the contents of the Event log.
Running Config is the current running-config.
This field only appears when you enter the command from the Primary RPM.
Example (S4820T)
Dell# show redundancy
-- Stack-unit Status --
------------------------------------------------
Mgmt ID: 0
Stack-unit ID: 0
Stack-unit Redundancy Role: Primary
Stack-unit State: Active
Stack-unit SW Version: FIT-R2D2-1-0-0-89
Link to Peer: Down
Peer Stack-unit: not present
-- Stack-unit Redundancy Configuration --
------------------------------------------------
Primary Stack-unit: mgmt-id 0
Auto Data Sync: Full
Failover Type: Hot Failover
Auto reboot Stack-unit: Disabled
Auto failover limit: 3 times in 60 minutes
-- Stack-unit Failover Record --
------------------------------------------------
Failover Count: 0
Last failover timestamp: None
Last failover Reason: None
Last failover type: None
-- Last Data Block Sync Record: --
------------------------------------------------
Stack Unit Config: no block sync done
Start-up Config: no block sync done
Runtime Event Log: no block sync done
Running Config: no block sync done
ACL Mgr: no block sync done
LACP: no block sync done
STP: no block sync done
SPAN: no block sync done
High Availability (HA) 651