Users Guide

Version Description
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
pre-6.2.1.1 Introduced on the E-Series.
Example
Dell(conf-if-vl-100)# show config
!
interface Vlan 100
no ip address
no shutdown
Dell(conf-if-vl-100)#
show vlan
Display the current VLAN configurations on the switch.
S4820T
Syntax
show vlan [brief | id vlan-id | name vlan-name]
Parameters
brief (OPTIONAL) Enter the keyword brief to display the following information:
VLAN ID
VLAN name (left blank if none is configured)
Spanning Tree Group ID
MAC address aging time
IP address
id vlan-id (OPTIONAL) Enter the keyword id then a number from 1 to 4094. Only
information on the VLAN specified is displayed.
name vlan-name (OPTIONAL) Enter the keyword name then the name configured for the VLAN.
Only information on the VLAN named is displayed.
Command Modes
EXEC
EXEC Privilege
Command History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
Networking OS Command Line Reference Guide.
Version Description
9.8(1.0) Introduced on the Z9100–ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
Layer 2 990